Strona 2 - Caution

2 Specifications Dimensions Model Chamber Size in (cm) Capacity feet3 (liters) Overall Size in (cm) Maximum Number of Shelf Positions Exhaust Dime

Strona 3

3 Temperature Model RFD 1-42-2E Time to Temperature 25ºC – 100ºC (approximate minutes with 25ºC – 200ºC no load) 25ºC – 343ºC 4 10 35 Recovery Ti

Strona 4

4 Power Line voltages may vary in some geographical locations. If your line voltage is much lower than the oven voltage rating, warm up time will b

Strona 5 - PREFACE

5 THEORY OF OPERATION This section details the function and operation of assemblies and subassemblies on the Despatch RFD1-42-2E Ovens. These ovens

Strona 6

6 Damper Control The oven is equipped with a manually adjustable damper mechanism. The damper control arm is located on the front panel of the oven

Strona 7 - TABLE OF CONTENTS

7 Full Open Position When the fresh air damper is in the full open position, the chamber will operate at its minimum operating temperature. Fricti

Strona 8

8 OVEN INSTRUCTIONS The INSTRUCTIONS section provides directions for unpacking, installation, operation and maintenance of the RFD 1-42-2E oven. Un

Strona 9 - Special Features

9 Set-up 1. Select the location for installing your oven. If solvents are going to be used in the oven, you must install an exhaust stack to the

Strona 10 - Specifications

10 Operating Users and operators of this oven must comply with operating procedures and training of operating personnel as required by the Occupatio

Strona 11 - Temperature

11 Loading the Oven Despatch Industries cannot be responsible for either the process or process temperature used, or for the quality of the product

Strona 12

Thank you for choosing Despatch Industries. We appreciate the opportunity to work with you and to meet your heat processing needs. We believe t

Strona 13 - THEORY OF OPERATION

12 Pre-Startup Checklist  Know the system. Read this manual carefully. Make use of its instructions and explanations. Safe, continuous, satisfa

Strona 14 - Damper Control

13 Startup For fastest oven heat-up time, close the fresh-air vent. After the desired temperature is reached, the vent may be adjusted as needed.

Strona 15 - Other Damper Settings

14 CONTROL INSTRUCTIONS The special features of the Protocol PlusTM control include: PID tuning Ramp/Soak programming of up to 64 segments Se

Strona 16 - OVEN INSTRUCTIONS

15 Protocol Plus Faceplate and Wiring Diagram

Strona 17 - All grounding and safety

16 Operating Modes The Protocol Plus control has five modes of operation available: Stopped Mode: All control and relay outputs are off. Stopped M

Strona 18 - Operating

17 High Limit The control has an integrated high limit function which will disable the heater output when tripped. If the high limit does trip, the

Strona 19 - Loading the Oven

18 Displays The Protocol Plus control has two displays. A dedicated LED upper display shows the oven temperature. A two-line LCD lower display provi

Strona 20 - Pre-Startup Checklist

19 Outputs The Protocol Plus control has seven different outputs available. Heating output: The control output is a DC voltage open-collector out

Strona 21 - Startup

20 Relay (Continued) Use the Relay Card Optional Ay p/n 144562 to add relays to the standard controller. Each relay card contains two relays (maximum

Strona 22 - Theory of Control Operation

21 INSTRUCTIONS Start-Up These instructions are provided as a quick reference for operating the Protocol Plus control. If the Profile Mode is to be

Strona 24 - Fast Start Mode

22 Operation Manual Mode Press the Select key until Manual is displayed (note you can press the Run key at any time to activate Manual Mode). 1.

Strona 25 - Indicators

23 Timer Mode 1. Press the Select key until Timer is displayed (note you can press the Run key at any time to activate Timer Mode). 2. Press the

Strona 26 - Key Functions

24 Profile Mode 1. Press the Select key until Profile is displayed. “None” may be displayed if a profile has not been selected or no profiles ente

Strona 27 - Outputs

25 Note that once you activate Auto Start, you can continue to use all operating modes as normal. If an operating mode is running at the time of a p

Strona 28 - Optional Software

26 Instructions for Setup Mode Pages Program Page Programming of the profiles is provided on the Program Page. Eight profiles are available with up

Strona 29 - Start-Up

27 Menu Item Display Description Ramp Time Seg 1 Pro-1 Seg-1 Ramp Time Ramp time for segment 1 of profile Event 1 Set Value* Pro-1 Seg-1 Ramp Event

Strona 30 - Operation

28 Profile # There are eight profiles available. Segment# Recipe segments 1 through 8 may be programmed, each with its own set of events, ramp and

Strona 31 - Timer Mode

29 Sample Profile Programming Table Profile Number____1______ Profile Name__________ Seg-ment Ramp Soak Time Events Temp-erature Time Events 1

Strona 32 - Auto Start Mode

30 Auto Start Page The Auto Start Page can be configured to automatically start Manual, Timer or Profile Mode at a specified time and day. Note that

Strona 33

31 Menu Item Display Description Range Enable Autostart Auto Start Enable Enable (yes) or disable (no) the Autostart function No, Yes Sunday mode Au

Strona 35

32 PID Page The PID Page contains parameters which control the response to the setpoint and process variable input. To access the PID Page, enter t

Strona 36 - Profile #

33 Control Page The Control Page contains various parameters which control miscellaneous functions. To access the Control Page, enter the Setup Mode

Strona 37 - Sample Profile

34 Communication Page (optional) The Communication Page contains parameters for the communications feature. To access the Communications Page, enter

Strona 38 - Auto Start Page

35 Relay Outputs Page (optional) The Relay Outputs Page configures the four alarm/event outputs. Each output has a dedicated indicator light and can

Strona 39

36 Test Page The Test Page contains parameters which allow manual control of the heat control and optional relay outputs and should be used only for

Strona 40 - PID Page

37 Zone Calibration Page The Zone Calibration Page allows adjustment of the displayed temperature versus the actual temperature measured by the cont

Strona 41 - Control Page

38 As an example, the control is displaying 400°F with the setpoint being 400°F, but the center of the oven chamber is actually 395°F. This can occu

Strona 42 - Real Time Clock Page

39 Sensor Calibration Page The Sensor Calibration Page has parameters which can change the internal calibration of the temperature sensor input sign

Strona 43

40 19. Connect a calibration instrument with a type J thermocouple output to the control sensor input. 20. Connect a voltage measurement device t

Strona 44 - Test Page

41 Enable Page The Enable Page controls access to the other Setup Pages. The setpoint minimum and maximum values, and the security passwords are al

Strona 45 - Zone Calibration Page

i PREFACE This manual is your guide to the Despatch oven. It is organized to give you the information you need quickly and easily. The INTRODUCTION

Strona 46

42 Digital Inputs (optional) The Protocol Plus control can be run by external inputs wired to the control from an external source such as a PLC or

Strona 47 - Sensor Calibration Page

43 Error Messages and Alarms The Alarm Status Hi-limit LED is flashing. This indicates a problem with the thermocouple, or the Hi-limit setpoint h

Strona 48

44 Quick Reference and Default Values Program Page Menu Item Display Default Range Setting Ramp Time Seg 1 Pro-1 Seg-1 Ramp Time 00:00 00m00s to 99

Strona 49 - Enable Page

45 Programming Table Profile Number__________ Profile Name__________ Seg-ment Ramp Soak Time Events Temp-erature Time Events 1 2 3 4 1 2 3 4 1

Strona 50 - Digital Inputs (optional)

46 Autostart Menu Item Display Default Range Setting Enable Autostart Auto Start Enable No No, Yes Sunday mode Auto Start Sun Mode Off Off, Manual,

Strona 51 - Error Messages and Alarms

47 Control Menu Item Display Default Range Setting Cycle Time Control Cycle Time 1 1 to 60 seconds High limit setpoint Control Hi-Lim SP Max HiLimS

Strona 52

48 Real Time Clock Menu Item Display Default Range Setting Day of the week Clock Day Mon Sun, Mon, Tue, Wed, Thu, Fri, Sat Time of day Clock HH:MM

Strona 53

49 Test Menu Item Display Default Range Setting Heater output Test HeatOut Off On High limit relay Test HiLimOut Off On Relay 1 output Test Rly1 O

Strona 54

50 Enable Page Menu Item Display Default Range Setting Profiles Enable Profile 1-8 Yes Yes or No Autostart Enable Auto Start No Yes or No ** PID E

Strona 55

51 Technical Specifications UL, cUL listed: UL file E136675 CE compliance to: EMC Directive 89-366/EEC European Standard EN55011/1991 Europea

Strona 56

ii Revision B: drawings added Revision C: drawings updated Revision D: Preface modified “Operating Environment” note added to Operating se

Strona 57

52 MAINTENANCE Do not attempt any service on this oven before opening the main power disconnect switch. Checklist  Keep equipment clean. Gr

Strona 58

53 Tests Tests should be performed carefully and regularly. The safety of personnel as well as the condition of equipment may depend upon the pro

Strona 59 - Technical Specifications

54 Replacement Parts To order or return parts, contact the Service Products Division at Despatch. The Service Products features our Response Cen

Strona 60 - Checklist

55 Protocol Plus™ Instrument (Tools needed: 1/4" socket driver with #1 bit, #2 Phillips screwdriver) 1. Disconnect the power. 2. Unplug al

Strona 61

56 Fan Motor (Tools needed: Screwdriver, 5/32 inch Allen wrench, one quarter (¼) inch socket set) 1. Remove the left and right inside walls.

Strona 62 - Replacement

57 TROUBLESHOOTING Equipment which operates for long periods of time may develop problems. Below are possible problems and suggested solutions. I

Strona 63 - Protocol Plus™ Instrument

58 Difficulty Probable Cause Suggested Remedy Erratic temp. or inaccurate temp. Protocol™ malfunction Improper tuning parameters Protocol™ misca

Strona 64 - Fan Motor

59 DRAWINGS Electrical drawings for the RAD/RFD series are found on the next six pages.

Strona 67 - DRAWINGS

iii TABLE OF CONTENTS INTRODUCTION ...

Strona 72

66 APPENDIX Temperature Scale Conversion (C/F) The Protocol Plus controller can be operated in either C or F. The default setting for the contro

Strona 73

67 Optional MRC5000 Recorder Setup The temperature is retransmitted to the Recorder from the Controller. Set up the Recorder as follows: 1. Make

Strona 74 - APPENDIX

iv PID Page ....... 32 Control Page ...

Strona 75

1 INTRODUCTION This section provides an overview of the Despatch RFD Series forced air oven. The RFD Series Ovens have the most effective heat dist